<?xml version="1.0" encoding="ISO-8859-1"?> 
<?xml-stylesheet type="text/xsl" href="rc4docs.xsl"?>
   <Document>
      <DocumentName><![CDATA[DOE O 413.3 Program and Project Management for the Acquisition of Capital Assets]]></DocumentName>
      <DocumentId><![CDATA[DOE O 413.3]]></DocumentId>
      <DocumentOpenDate>11/29/2004</DocumentOpenDate>
      <DocumentCloseDate>12/13/2004</DocumentCloseDate>
      <DocumentResolutionDate>12/17/2004</DocumentResolutionDate>
      <MajorComments>
         <Section>
            <SectionTitle><![CDATA[Overall Comments]]></SectionTitle>
            <SectionContent><![CDATA[Please provide your overall comments about this document.
Note: this 'paragraph' is not part of the original document.]]></SectionContent>
            <Organization>
               <OrganizationName><![CDATA[Ames Labortatory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Argonne National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Associate Manager for Science & Technology, Richland]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bechtel Hanford]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bechtel Nevada]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Berkeley Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Anne Raible]]></SourceUsername>
                  <SourceTitle><![CDATA[Berkeley Site Office POC]]></SourceTitle>
                  <SourceSite><![CDATA[Berkeley Site Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[Subject Matter Expert warren.yip@bso.science.doe.gov
1.  Page 5:  paragraph g.

Change 'Federal Project Manager' to 'Federal Project Director' in two places to be consistent with the DOE M 413.3 of March 31, 2003.

2.  Page I-1 Critical Decisions

Change CD-1, Approve 'Preliminary Baseline Range,' should be changed to CD-1, Approve 'Alternative Selection and Cost Range,' to be consistent with the DOE M 413.3 of March 31, 2003.

3.   Page I-2 

Change CD-1, Approve 'Preliminary Baseline Range,' should be changed to CD-1, Approve 'Alternative Selection and Cost Range,' to be consistent with the DOE M 413.3 of March 31, 2003.
 
4.  Page II-1 (and II-2)

Change 'Federal Project Manager' to 'Federal Project Director' in two places to be consistent with the DOE M 413.3 of March 31, 2003.

5.  Attachment #2 Page 2

Change 'Federal Project Manager' to 'Federal Project Director' in two places to be consistent with the DOE M 413.3 of March 31, 2003.

6.  Attachment #4 Page 1

Change Approve 'Preliminary Baseline Range,' should be changed to Approve 'Alternative Selection and Cost Range,' to be consistent with the DOE M 413.3 of March 31, 2003.

7.  Attachment #4 Page 2
 
Change Approve 'Preliminary Baseline Range/Proposed Work Plan,' should be changed to Approve 'Alternative Selection and Cost Range/Proposed Work Plan,' to be consistent with the DOE M 413.3 of March 31, 2003.

Subject Matter Expert barry.savnik@bso.science.doe.gov
This revision to O 413.3 has not addressed the direction of the Under Secretary memo of March 31, 2003 which was "I have directed OMBE to publish revisions to DOE O 413.3, Program and Project Management for the Acquisition of Capital Assets, to make it consistent with the manual."  

This revision demonstrates the confusion that is created when there are two requirement documents for the same subject.  i.e. they are never consistent.  

Strongly encourage that all Project Management requirements be placed in one directive; logically DOE O 413.3.  In this case, the Manual could be used for guidance only.

Subject Matter Expert j.krupa@bso.science.doe.gov
BSO's understanding was that the next revision to O413.3 was to reconcile differences with M413.3 such that the new Order would be the governing directive to which DOE and the Labs would manage projects.  This does not appear to be the case with this revision.  Is this planned; when will it happen?  Please clarify the relationship between Order and Manual, especially regarding requirements vs. guidance.

Subject Matter Expert warren.yip@bso.science.doe.gov
1.  Page 5:  paragraph g.

Change "Federal Project Manager" to "Federal Project Director" in two places to be consistent with the DOE M 413.3 of March 31, 2003.

2.  Page I-1 Critical Decisions

Change CD-1, Approve "Preliminary Baseline Range," should be changed to CD-1, Approve "Alternative Selection and Cost Range," to be consistent with the DOE M 413.3 of March 31, 2003.

3.   Page I-2 

Change CD-1, Approve "Preliminary Baseline Range," should be changed to CD-1, Approve "Alternative Selection and Cost Range," to be consistent with the DOE M 413.3 of March 31, 2003.
 
4.  Page II-1 (and II-2)

Change "Federal Project Manager" to "Federal Project Director" in two places to be consistent with the DOE M 413.3 of March 31, 2003.

5.  Attachment #2 Page 2

Change "Federal Project Manager" to "Federal Project Director" in two places to be consistent with the DOE M 413.3 of March 31, 2003.

6.  Attachment #4 Page 1

Change Approve "Preliminary Baseline Range," should be changed to Approve "Alternative Selection and Cost Range," to be consistent with the DOE M 413.3 of March 31, 2003.

7.  Attachment #4 Page 2
 
Change Approve "Preliminary Baseline Range/Proposed Work Plan," should be changed to Approve "Alternative Selection and Cost Range/Proposed Work Plan," to be consistent with the DOE M 413.3 of March 31, 2003.]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bonneville Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Brookhaven National  Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[BWXT Pantex, LLC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Carlsbad Area Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Carlsbad Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[CH2MHill]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Chicago Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Critique]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Departmental Representatives Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Directives Management Team]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[DynMcDermott Petroleum Operations]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fermi National Accelerator Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fernald]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fluor Hanford Inc]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Golden Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Grand Junction]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CIO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CN]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CR]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters ED]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EH]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EIA]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EM]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Joni Boone]]></SourceUsername>
                  <SourceTitle><![CDATA[EM DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters EM]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[Subject Matter Expert leonard.mucciaro@em.doe.gov
The new order is not consistent with the Manual There are a significant number of changes that are required before the Order should be issued. OECM has had a team working on this for almost a year.  Incorporate those changes as well into this revision.  Adding a paragraph to address only safeguards and security requirements is understandable but unaceptable because of the differences between the manual and order. EM has been waiting over two years for the information on ER and D&D projects to be properly addressed in both the manual and order]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Not Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[These comments are outside the scope of the proposed page change revision.  OECM is concurrently working on revising the full Order to bring it upto date and make it consistent with the Manual.  These comments will be considered in that revision.]]></ResponseContent>
               </Response>
               <Concurrence><![CDATA[Concur/No Comment]]></Concurrence>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters FE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters GC]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Richard Farman]]></SourceUsername>
                  <SourceTitle><![CDATA[GC DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters GC]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[

Subject Matter Expert steve.duarte@hq.doe.gov
This change does not apply to contractors and does not appear to impose requirements on members of the public that would require notice and comment rulemaking.  No action by the OPI is required in response to this comment.

]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters HG]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters IG]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters IN]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters LM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters MBE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NA]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Diane Gillis]]></SourceUsername>
                  <SourceTitle><![CDATA[NA Directives Point of Contact]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters NA]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[Note: While these comments are outside the scope of this review, they are provided for consideration/appropriate action.

Comment:  Add a paragraph 8 to Chapter VII to read as follows:
8.	Counterintelligence.  Counterintelligence is an integral part of project planning and execution.  Counterintelligence goals and objectives must be considered in acquisition of capital assets in initial phase of the project and throughout each phase.  (NA-3.2/Burch)

Comment:  The directive still does not include provisions for another key program that should be a factor in program and project management for the acquisition of capital assets--emergency management.  
A provision almost identical to the proposed change for safeguards and security should be included as Chapter VII, paragraph 8:
8.	Emergency Management.  Emergency Management is an integral part of project planning and execution.  Acquisition of capital assets must address applicable emergency management requirements early in the initial phase of the project and integrate these requirements along with safety, quality, and environmental protection in every phase of the acquisition process.
(NA-40/Fairobent)

Comment:  There are some inconsistencies between the revised Order and Manual M 413.3-1. Here are a few examples.  The revised Order still uses the term Federal Project Manager where the Manual introduced the term Project Director.  Approval levels and allowable delegation are not consistent between the two documents.  The revised Order still spells out Baseline Change Levels 0 through 3 whereas the Manual eliminated these levels and introduced the term “deviation.”   Since the revised Order is going to be officially released, either the Order or the Manual should be modified so the two documents are consistent.  (Livermore/Cyganowski - SME/Graham)

Comment:  Deputy Secretary McSlarrow issued DOE M 413.3-1 as the controlling document over DOE O 413.3, stating in the cover Memorandum for the Manual:  "Pending the update of DOE O 413.3, the manual takes precedence where there is a conflict between the processes, procedures and approval levels contained in the manual and those in the Order and other project management policy statements, ....”  This needs to be covered under this revision since conflicts between the Order and Manual still exist.  (Sandia/Martinez)]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Not Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[These comments are outside the scope of the proposed page change revision.  OECM is concurrently working on revising the full Order to bring it upto date and make it consistent with the Manual.  These comments will be considered in that revision.]]></ResponseContent>
               </Response>
               <Concurrence><![CDATA[Concur/No Comment]]></Concurrence>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NTEU]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters OA]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters OPI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters PC-1]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters PO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters RW]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters SC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters SO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Honeywell FM&T (Kansas City Plant)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Idaho Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Idaho Operations Office-EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[INL - NE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[INL-ICP-EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Kaiser-Hill Company, LLC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Kansas City Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Lawrence Berkeley Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Lawrence Livermore National Laboratory]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Lisla Damoulos]]></SourceUsername>
                  <SourceTitle><![CDATA[LLNL Office of Contract Management DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Lawrence Livermore National Laboratory]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[Subject Matter Expert graham6@llnl.gov
One significant observation is submitted. There are some inconsistencies between the revised Order and Manual M 413.3-1. Here are a few examples. The revised Order still uses the term Federal Project Manager where the Manual introduced the term Project Director. Approval levels and allowable delegation are not consistent between the two documents. The revised Order still spells out Baseline Change Levels 0 through 3 whereas the Manual eliminated these levels and introduced the term 'deviation'.

'Suggested Comment'  - Since the revised Order is going to be officially released, either the Order or the Manual should be modified so the two documents are consistent.]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Livermore Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Walter  Cyganowski]]></SourceUsername>
                  <SourceTitle><![CDATA[LSO DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Livermore Site Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[

Lisla Damoulos (LLNL Office of Contract Management DPC) for Lawrence Livermore National Laboratory
Subject Matter Expert graham6@llnl.gov
One significant observation is submitted. There are some inconsistencies between the revised Order and Manual M 413.3-1. Here are a few examples. The revised Order still uses the term Federal Project Manager where the Manual introduced the term Project Director. Approval levels and allowable delegation are not consistent between the two documents. The revised Order still spells out Baseline Change Levels 0 through 3 whereas the Manual eliminated these levels and introduced the term 'deviation'.

'Suggested Comment'  - Since the revised Order is going to be officially released, either the Order or the Manual should be modified so the two documents are consistent.

]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Los Alamos National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Los Alamos Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[NA Service Center]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[National Energy Technology Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[National Renewable Energy Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Nevada Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oak Ridge National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oak Ridge Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oakland Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Office of Energy Assurance]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Office of River Protection]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Ohio Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[OSTI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Pacific Northwest National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Pantex Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Portsmouth Paducah Project Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Princeton Plasma Physics Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Richland Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Rocky Flats Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Sandia National Laboratories]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Sandia Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Bernadette Martinez]]></SourceUsername>
                  <SourceTitle><![CDATA[SSO DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Sandia Site Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No comments on the proposed section change. However, Deputy Secretary McSlarrow had clearly issued  the Manual 413.3-1 as the controlling document over the Order 413.3, stating in the cover Memorandum for the Manual:  "Pending the update of DOE 0 413.3, the manual takes precedence where there is a conflict between the processes, procedures and approval levels contained in the manual and those in the Order and other 
project management policy tatements, ... This needs to be covered under this revision since conflicts between the Order and Manual still exists.]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Savannah River EM Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Savannah River Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Southeastern Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Southwestern Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Stanford Linear Accelerator Center]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Stanford Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Thomas Jefferson National Accelerator Facility]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[University of California]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Wackenhut Services Inc (SRS)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Wackenhut Services Inc. (Nevada)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[West Valley Demonstration Project]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Western Area Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Westinghouse Savannah River Corp.]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Westinghouse Savannah River Corp. for SR-EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[WIPP]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 (BWXT)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 (WSI)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 Site Office]]></OrganizationName>
            </Organization>
         </Section>
         <Section>
            <SectionTitle><![CDATA[Chapter VII, paragraph 7]]></SectionTitle>
            <SectionContent><![CDATA[The following is inserted as paragraph 7 in Chapter VII. To read the paragraph in 
context, see page VII-2 of the PDF file.

7.	Safeguards and Security.  Safeguards and Security is an integral part of project planning 
	and execution.  Acquisition of capital assets must address applicable Safeguards and 
	Security requirements early in the initial phase of the project and integrate these 
	requirements along with safety, quality, and environmental protection in every phase of 
	the acquisition process.

]]></SectionContent>
            <Organization>
               <OrganizationName><![CDATA[Ames Labortatory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Argonne National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Associate Manager for Science & Technology, Richland]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bechtel Hanford]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bechtel Nevada]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Berkeley Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bonneville Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Brookhaven National  Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[BWXT Pantex, LLC]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Lynda McCollum]]></SourceUsername>
                  <SourceTitle><![CDATA[MHC DPC]]></SourceTitle>
                  <SourceSite><![CDATA[BWXT Pantex, LLC]]></SourceSite>
               </Source>
               <Comments><![CDATA[Attachment 1, Contractor Requirements Document
Page 2, Number 11
Reference to DOE Order 414.1A should be DOE Order 414.1B.]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Carlsbad Area Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Carlsbad Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[CH2MHill]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Chicago Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Critique]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Departmental Representatives Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Directives Management Team]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[DynMcDermott Petroleum Operations]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fermi National Accelerator Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fernald]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fluor Hanford Inc]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Golden Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Grand Junction]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CIO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CN]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Michael Dixon]]></SourceUsername>
                  <SourceTitle><![CDATA[CN DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters CN]]></SourceSite>
               </Source>
               <Comments><![CDATA[Subject Matter Expert yvonne.burch@cn.doe.gov
Add a para 8 to Chapter VII to read as follows:


8.    Counterintelligence.  Counterintelligence is an integral part of project planning and execution.  Counterintelligence goals and objectives must be considered in acquisition of capital assets in initial phase of the project and throughout each phase.]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Not Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[This comment is outside the scope of the proposed page change revision.  OECM is concurrently working on revising the full Order to bring it upto date and make it consistent with the Manual.  This comment will be considered in that revision.]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CR]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters ED]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EH]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EIA]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters FE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters GC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters HG]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters IG]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters IN]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters LM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters MBE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NA]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NTEU]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters OA]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters OPI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters PC-1]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters PO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters RW]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters SC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters SO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Honeywell FM&T (Kansas City Plant)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Idaho Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Idaho Operations Office-EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[INL - NE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[INL-ICP-EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Kaiser-Hill Company, LLC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Kansas City Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Lawrence Berkeley Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Lawrence Livermore National Laboratory]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Lisla Damoulos]]></SourceUsername>
                  <SourceTitle><![CDATA[LLNL Office of Contract Management DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Lawrence Livermore National Laboratory]]></SourceSite>
               </Source>
               <Comments><![CDATA[Subject Matter Expert graham6@llnl.gov
It appears that the only change in the revised Order O 413.3 is the addition of paragraph 7 -  Safeguards and Security in Chapter VII. There is no comment on the added paragraph since the wording seems appropriate.

"Suggested Comment" - Add   "7.   Safeguards and Security"   to the Table of Contents.]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Livermore Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Walter  Cyganowski]]></SourceUsername>
                  <SourceTitle><![CDATA[LSO DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Livermore Site Office]]></SourceSite>
               </Source>
               <Comments><![CDATA[

Lisla Damoulos (LLNL Office of Contract Management DPC) for Lawrence Livermore National Laboratory
Subject Matter Expert graham6@llnl.gov
It appears that the only change in the revised Order O 413.3 is the addition of paragraph 7 -  Safeguards and Security in Chapter VII. There is no comment on the added paragraph since the wording seems appropriate.

"Suggested Comment" - Add   "7.   Safeguards and Security"   to the Table of Contents.

]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Los Alamos National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Los Alamos Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[NA Service Center]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[National Energy Technology Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[National Renewable Energy Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Nevada Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oak Ridge National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oak Ridge Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oakland Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Office of Energy Assurance]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Office of River Protection]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Ohio Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[OSTI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Pacific Northwest National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Pantex Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Ron Holm]]></SourceUsername>
                  <SourceTitle><![CDATA[Pantex Site Office DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Pantex Site Office]]></SourceSite>
               </Source>
               <Comments><![CDATA[Lynda McCollum (BWXT DPC) for BWXT Pantex, LLC wrote on 12/08/2004 15:16:17 Mountain Time:
Attachment 1, Contractor Requirements Document
Page 2, Number 11
Reference to DOE Order 414.1A should be DOE Order 414.1B.]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Portsmouth Paducah Project Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Princeton Plasma Physics Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Richland Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Rocky Flats Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Sandia National Laboratories]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Sandia Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Savannah River EM Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Savannah River Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Southeastern Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Southwestern Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Stanford Linear Accelerator Center]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Stanford Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Thomas Jefferson National Accelerator Facility]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[University of California]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Wackenhut Services Inc (SRS)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Wackenhut Services Inc. (Nevada)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[West Valley Demonstration Project]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Western Area Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Westinghouse Savannah River Corp.]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Westinghouse Savannah River Corp. for SR-EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[WIPP]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 (BWXT)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 (WSI)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 Site Office]]></OrganizationName>
            </Organization>
         </Section>
      </MajorComments>
      <MinorComments>
         <Section>
            <SectionTitle><![CDATA[Overall Comments]]></SectionTitle>
            <SectionContent><![CDATA[Please provide your overall comments about this document.
Note: this 'paragraph' is not part of the original document.]]></SectionContent>
            <Organization>
               <OrganizationName><![CDATA[Ames Labortatory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Argonne National Laboratory]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Don Schmitt]]></SourceUsername>
                  <SourceTitle><![CDATA[ANL DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Argonne National Laboratory]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Associate Manager for Science & Technology, Richland]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bechtel Hanford]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bechtel Nevada]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Berkeley Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Anne Raible]]></SourceUsername>
                  <SourceTitle><![CDATA[Berkeley Site Office POC]]></SourceTitle>
                  <SourceSite><![CDATA[Berkeley Site Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[

Subject Matter Expert j.krupa@bso.science.doe.gov
-REFERENCES Paragraph 6.i., refers to "DOE M 413.X" and says "to be issued" rather than giving the date.  Other references may not be current.
-Para 3.e. Implementation review 12 months after publication- is this a current requirement?
-Para 5.g. Refers to the "Federal Project Manager" rather than "Federal Project Director".
-Chapter 1, CD-2 "Approve Preliminary Baseline Range" conflicts with Chapter 2 of the Manual "Approve Alternative Selection and Cost Range"- probably the manual should be changed.


]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bonneville Power Administration]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Janet Lubach]]></SourceUsername>
                  <SourceTitle><![CDATA[BPA DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Bonneville Power Administration]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Brookhaven National  Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[BWXT Pantex, LLC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Carlsbad Area Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Carlsbad Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[CH2MHill]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Chicago Operations Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Lynette Kane]]></SourceUsername>
                  <SourceTitle><![CDATA[CH DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Chicago Operations Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Critique]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Departmental Representatives Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Directives Management Team]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[DynMcDermott Petroleum Operations]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fermi National Accelerator Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fernald]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fluor Hanford Inc]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Golden Field Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Allen Hays]]></SourceUsername>
                  <SourceTitle><![CDATA[GFO DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Golden Field Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[
Karen Stiveson (NREL DPC) for National Renewable Energy Laboratory
NREL currently has no compliance issues and will work diligently to remain in compliance with the intent of the CRD.  However, full implementation of requirements specified in the CRD will result in major cost and resource impacts for construction line item projects.

]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Grand Junction]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CIO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CN]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Michael Dixon]]></SourceUsername>
                  <SourceTitle><![CDATA[CN DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters CN]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CR]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters ED]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Myrna Turturro]]></SourceUsername>
                  <SourceTitle><![CDATA[ED DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters ED]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EH]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Murari Sharma]]></SourceUsername>
                  <SourceTitle><![CDATA[Delegate]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters EH]]></SourceSite>
               </Source>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
               <Source>
                  <SourceUsername><![CDATA[Gina Simpson]]></SourceUsername>
                  <SourceTitle><![CDATA[Delegate]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters EH]]></SourceSite>
               </Source>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
               <Source>
                  <SourceUsername><![CDATA[Beverly Stephens]]></SourceUsername>
                  <SourceTitle><![CDATA[Delegate]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters EH]]></SourceSite>
               </Source>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EIA]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EM]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Joni Boone]]></SourceUsername>
                  <SourceTitle><![CDATA[EM DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters EM]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[
Linda C. Wright (SRO EM DPC) for Savannah River EM Office


Bruce Whealton (WSRCEM DPC) for Westinghouse Savannah River Corp. for SR-EM
No Comment

Sandra Bishop (Wackenhut Services Inc DPC) for Wackenhut Services Inc (SRS)

Subject Matter Expert stephen.fraser@srs.gov
No Comment





Karen Moses (ID-EM DPC) for Idaho Operations Office-EM
No Comment

Delegate Jay D. Bilyeu for Savannah River EM Office
No Comment

Susan Coleman (Office of River Protection DPC) for Office of River Protection
No Comment

Joanne Shadel (RL DPC) for Richland Operations Office
No Comment

Subject Matter Expert leonard.mucciaro@em.doe.gov
No Comment

]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters FE]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Suzanne Iannucci]]></SourceUsername>
                  <SourceTitle><![CDATA[FE DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters FE]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters GC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters HG]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters IG]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters IN]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters LM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters MBE]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Mark Hively]]></SourceUsername>
                  <SourceTitle><![CDATA[Delegate]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters MBE]]></SourceSite>
               </Source>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NA]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Diane Gillis]]></SourceUsername>
                  <SourceTitle><![CDATA[NA Directives Point of Contact]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters NA]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[Comment:  Assuming the new congressional language gets finalized raising the GPP limit from $5 million to $10 million the Order will have to be revised.  The applicability of DOE O 413.3 is currently for projects at $5 million.  The Order may have to be revised to indicate at $10 million or at the GPP limit.  (Livermore/Cyganowski - SME/Hilliard)

Comment:  Attachment 1, Contractor Requirements Document Page 2, Number 11 Reference to DOE Order 414.1A should be DOE Order 414.1B.  (Pantex/Pyzel - SME/McCollum)]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Not Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[This comment is outside the scope of the proposed page change revision.  OECM is concurrently working on revising the full Order to bring it upto date and make it consistent with the Manual.  This comment will be considered in that revision.]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NE]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Barbara Cramer]]></SourceUsername>
                  <SourceTitle><![CDATA[NE DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters NE]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NTEU]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters OA]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Sharon Edge-Harley]]></SourceUsername>
                  <SourceTitle><![CDATA[OA DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters OA]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters OPI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters PC-1]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters PO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters RW]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Sharon Pollock]]></SourceUsername>
                  <SourceTitle><![CDATA[RW DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters RW]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters SC]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Jennifer Kelley]]></SourceUsername>
                  <SourceTitle><![CDATA[SC DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters SC]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters SO]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Geralyn Praskievicz]]></SourceUsername>
                  <SourceTitle><![CDATA[SO DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters SO]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Honeywell FM&T (Kansas City Plant)]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Susie Barrett]]></SourceUsername>
                  <SourceTitle><![CDATA[Directives Point of Contact]]></SourceTitle>
                  <SourceSite><![CDATA[Honeywell FM&T (Kansas City Plant)]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[HFMT currently meets this requirement in our project planning activities. (Dan Gehrke)]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Idaho Operations Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Karen Moses]]></SourceUsername>
                  <SourceTitle><![CDATA[ID DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Idaho Operations Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Idaho Operations Office-EM]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Karen Moses]]></SourceUsername>
                  <SourceTitle><![CDATA[ID-EM DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Idaho Operations Office-EM]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[INL - NE]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Requirements Management]]></SourceUsername>
                  <SourceTitle><![CDATA[INL-NE DPC]]></SourceTitle>
                  <SourceSite><![CDATA[INL - NE]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[INL-ICP-EM]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Requirements Management]]></SourceUsername>
                  <SourceTitle><![CDATA[INL-ICP-EM DPC]]></SourceTitle>
                  <SourceSite><![CDATA[INL-ICP-EM]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Kaiser-Hill Company, LLC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Kansas City Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Lawrence Berkeley Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Lawrence Livermore National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Livermore Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Walter  Cyganowski]]></SourceUsername>
                  <SourceTitle><![CDATA[LSO DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Livermore Site Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[
Subject Matter Expert bob.hilliard@oak.gov.doe
No Comment

Subject Matter Expert
Lisla Damoulos, LLNL
Assuming the new congressional language  gets finalized raising the GPP limit from $5M to $10M the Order will have to be revised.  The applicability of 413.3 is currently for projects at $5M.  The Order may have to be revised to indicate at $10M or at the GPP limit.]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Los Alamos National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Los Alamos Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Myra Garcia-Pena]]></SourceUsername>
                  <SourceTitle><![CDATA[LASO DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Los Alamos Site Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[NA Service Center]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Yolanda Bolivar]]></SourceUsername>
                  <SourceTitle><![CDATA[AL DPC]]></SourceTitle>
                  <SourceSite><![CDATA[NA Service Center]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[National Energy Technology Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[National Renewable Energy Laboratory]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Karen Stiveson]]></SourceUsername>
                  <SourceTitle><![CDATA[NREL DPC]]></SourceTitle>
                  <SourceSite><![CDATA[National Renewable Energy Laboratory]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[NREL currently has no compliance issues and will work diligently to remain in compliance with the intent of the CRD.  However, full implementation of requirements specified in the CRD will result in major cost and resource impacts for construction line item projects.]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Nevada Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[David Ross]]></SourceUsername>
                  <SourceTitle><![CDATA[NV DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Nevada Site Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[
Richard D. Shook (WSI NV DPC) for Wackenhut Services Inc. (Nevada)
No Comment

]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oak Ridge National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oak Ridge Operations Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Jennifer Hamilton]]></SourceUsername>
                  <SourceTitle><![CDATA[OR DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Oak Ridge Operations Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oakland Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Office of Energy Assurance]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Office of River Protection]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Susan Coleman]]></SourceUsername>
                  <SourceTitle><![CDATA[Office of River Protection DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Office of River Protection]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Ohio Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[OSTI]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Bronie Dison]]></SourceUsername>
                  <SourceTitle><![CDATA[OSTI DPC]]></SourceTitle>
                  <SourceSite><![CDATA[OSTI]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Pacific Northwest National Laboratory]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Terry Dahl]]></SourceUsername>
                  <SourceTitle><![CDATA[PNNL DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Pacific Northwest National Laboratory]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Pantex Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Portsmouth Paducah Project Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Princeton Plasma Physics Laboratory]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Jim Graham]]></SourceUsername>
                  <SourceTitle><![CDATA[PPPL DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Princeton Plasma Physics Laboratory]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Richland Operations Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Joanne Shadel]]></SourceUsername>
                  <SourceTitle><![CDATA[RL DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Richland Operations Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Rocky Flats Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Sandia National Laboratories]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Rebecca Cayen]]></SourceUsername>
                  <SourceTitle><![CDATA[SNL DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Sandia National Laboratories]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Sandia Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Savannah River EM Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Linda C. Wright]]></SourceUsername>
                  <SourceTitle><![CDATA[SRO EM DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Savannah River EM Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[

Bruce Whealton (WSRCEM DPC) for Westinghouse Savannah River Corp. for SR-EM
No Comment

Sandra Bishop (Wackenhut Services Inc DPC) for Wackenhut Services Inc (SRS)

Subject Matter Expert stephen.fraser@srs.gov
No Comment



]]></Comments>
               <Source>
                  <SourceUsername><![CDATA[Jay D. Bilyeu]]></SourceUsername>
                  <SourceTitle><![CDATA[Delegate]]></SourceTitle>
                  <SourceSite><![CDATA[Savannah River EM Office]]></SourceSite>
               </Source>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Savannah River Site Office]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Linda C. Wright]]></SourceUsername>
                  <SourceTitle><![CDATA[SRSO DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Savannah River Site Office]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[

Bruce Whealton (WSRC DPC) for Westinghouse Savannah River Corp.
No Comment

Subject Matter Expert roxanne.jump@nnsa.srs.gov
No Comment

]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Southeastern Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Southwestern Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Stanford Linear Accelerator Center]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Stanford Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Thomas Jefferson National Accelerator Facility]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[University of California]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Wackenhut Services Inc (SRS)]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Sandra Bishop]]></SourceUsername>
                  <SourceTitle><![CDATA[Wackenhut Services Inc DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Wackenhut Services Inc (SRS)]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[S. Fraser]]></ApproverName>
               <Comments><![CDATA[
Subject Matter Expert stephen.fraser@srs.gov
No Comment

]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Wackenhut Services Inc. (Nevada)]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Richard D. Shook]]></SourceUsername>
                  <SourceTitle><![CDATA[WSI NV DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Wackenhut Services Inc. (Nevada)]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[West Valley Demonstration Project]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Western Area Power Administration]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Sue Silva]]></SourceUsername>
                  <SourceTitle><![CDATA[WAPA DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Western Area Power Administration]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Westinghouse Savannah River Corp.]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Bruce Whealton]]></SourceUsername>
                  <SourceTitle><![CDATA[WSRC DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Westinghouse Savannah River Corp.]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Westinghouse Savannah River Corp. for SR-EM]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Bruce Whealton]]></SourceUsername>
                  <SourceTitle><![CDATA[WSRCEM DPC]]></SourceTitle>
                  <SourceSite><![CDATA[Westinghouse Savannah River Corp. for SR-EM]]></SourceSite>
               </Source>
               <ApproverName><![CDATA[]]></ApproverName>
               <Comments><![CDATA[No Comment]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[WIPP]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 (BWXT)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 (WSI)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 Site Office]]></OrganizationName>
            </Organization>
         </Section>
         <Section>
            <SectionTitle><![CDATA[Chapter VII, paragraph 7]]></SectionTitle>
            <SectionContent><![CDATA[The following is inserted as paragraph 7 in Chapter VII. To read the paragraph in 
context, see page VII-2 of the PDF file.

7.	Safeguards and Security.  Safeguards and Security is an integral part of project planning 
	and execution.  Acquisition of capital assets must address applicable Safeguards and 
	Security requirements early in the initial phase of the project and integrate these 
	requirements along with safety, quality, and environmental protection in every phase of 
	the acquisition process.

]]></SectionContent>
            <Organization>
               <OrganizationName><![CDATA[Ames Labortatory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Argonne National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Associate Manager for Science & Technology, Richland]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bechtel Hanford]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bechtel Nevada]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Berkeley Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Bonneville Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Brookhaven National  Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[BWXT Pantex, LLC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Carlsbad Area Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Carlsbad Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[CH2MHill]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Chicago Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Critique]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Departmental Representatives Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Directives Management Team]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[DynMcDermott Petroleum Operations]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fermi National Accelerator Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fernald]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Fluor Hanford Inc]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Golden Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Grand Junction]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CIO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CN]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters CR]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters ED]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EH]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EIA]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters FE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters GC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters HG]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters IG]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters IN]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters LM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters MBE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NA]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Diane Gillis]]></SourceUsername>
                  <SourceTitle><![CDATA[NA Directives Point of Contact]]></SourceTitle>
                  <SourceSite><![CDATA[Headquarters NA]]></SourceSite>
               </Source>
               <Comments><![CDATA[Comment:  Add "7. Safeguards and Security" to the Table of Contents.  (Livermore/Cyganowski - SME/Graham)]]></Comments>
               <Response>
                  <ResponseLevel><![CDATA[Accepted]]></ResponseLevel>
                  <ResponseContent><![CDATA[Thanks.  Will do.]]></ResponseContent>
               </Response>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters NTEU]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters OA]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters OPI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters PC-1]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters PO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters RW]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters SC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Headquarters SO]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Honeywell FM&T (Kansas City Plant)]]></OrganizationName>
               <Source>
                  <SourceUsername><![CDATA[Susie Barrett]]></SourceUsername>
                  <SourceTitle><![CDATA[Directives Point of Contact]]></SourceTitle>
                  <SourceSite><![CDATA[Honeywell FM&T (Kansas City Plant)]]></SourceSite>
               </Source>
               <Comments><![CDATA[Subject Matter Expert cham@kcp.com
No Major comment for this paragraph.]]></Comments>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Idaho Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Idaho Operations Office-EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[INL - NE]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[INL-ICP-EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Kaiser-Hill Company, LLC]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Kansas City Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Lawrence Berkeley Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Lawrence Livermore National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Livermore Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Los Alamos National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Los Alamos Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[NA Service Center]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[National Energy Technology Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[National Renewable Energy Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Nevada Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oak Ridge National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oak Ridge Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Oakland Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Office of Energy Assurance]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Office of River Protection]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Ohio Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[OSTI]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Pacific Northwest National Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Pantex Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Portsmouth Paducah Project Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Princeton Plasma Physics Laboratory]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Richland Operations Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Rocky Flats Field Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Sandia National Laboratories]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Sandia Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Savannah River EM Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Savannah River Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Southeastern Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Southwestern Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Stanford Linear Accelerator Center]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Stanford Site Office]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Thomas Jefferson National Accelerator Facility]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[University of California]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Wackenhut Services Inc (SRS)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Wackenhut Services Inc. (Nevada)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[West Valley Demonstration Project]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Western Area Power Administration]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Westinghouse Savannah River Corp.]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Westinghouse Savannah River Corp. for SR-EM]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[WIPP]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 (BWXT)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 (WSI)]]></OrganizationName>
            </Organization>
            <Organization>
               <OrganizationName><![CDATA[Y-12 Site Office]]></OrganizationName>
            </Organization>
         </Section>
      </MinorComments>
   </Document>